• Login
    View Item 
    •   DSpace Home
    • Otros documentos científicos
    • CAD/CAM
    • View Item
    •   DSpace Home
    • Otros documentos científicos
    • CAD/CAM
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Análisis numérico comparativo defijadores para el tratamiento de fracturas proximales del fémur.

    Thumbnail
    View/Open
    2011 - Estrada - Análisis numérico comparativo de fijadores.pdf (316.5Kb)
    Date
    2011
    Author
    Bosch Cabrera, Jorge Alexander
    Estrada Cingualbres, Roberto Andrés
    Ramos Botello, Yoan Manuel
    Metadata
    Show full item record
    Abstract
    Múltiples son los dispositivos utilizados para lograr la consolidación de las fracturas proximales del fémur, algunos sufren roturas antes de ser retirados del paciente, ocasionando nuevas complicaciones al mismo. En esta investigación se presentan los resultados del análisis numérico realizado a un fijador interno del tipo placa DHS (Dinámic Hip Screw) y a un fijador externo monolateral con tornillo cefálico RALCA (Rodrigo Álvarez Cambras), con el propósito de determinar el comportamiento del estado tensional-deformacional de ambos dispositivos durante la consolidación ósea de fracturas proximales de cadera, bajo la marcha monopodal del paciente. Para la modelación geométrica de los dispositivos en cuestión se empleó el paquete de diseño en 3D SolidWorksy la simulación numérica se realizó con el empleo del paquete de análisis por elementos finitos Cosmos/Works. Los resultados muestran valores inferiores de las tensiones máximas en el fijador externo en comparación con las tensiones que surgen en la placa dinámica bajo la acción de las cargas actuantes en los modelos, por lo que se concluye que el primero posee mejores características resistivas, siendo recomendable su uso en pacientes de mayor peso corporal o que podrían realizar actividades físicas más activas durante su recuperación postoperatoria. Multiple are devices used to achieve the consolidation of proximal femur fractures, some suffering breakage before being removed from the patient, causing new complications to them. This research presents the results of the numerical analysis made to an internal fixer type plate DHS (Dinámic Hip Screw), and to a monolateral external fixer with RALCA (Rodrigo Alvarez Cambras) head screw, with the purpose of determining the behavior of the tensional-deformational State of both devices during the bone consolidation of proximal fracture of the hip, with patients walking using one leg. For the geometric modeling of the devices in question is employed the design package 3D SolidWorks and numerical simulation was carried out with the use of the analysis package by finite elements Cosmos/Works. The results show lower values of maximum stress in the external fixer in comparison with the stress that arise in the dynamic plate under the action of the acting loads on the models, so it can be concluded that the first possesses best resistive features, being recommended its use in patients having heavy weight or those who could make more active physical activities during their postoperative recovery.
    URI
    http://repositorio.uho.edu.cu/jspui/handle/uho/32
    Collections
    • CAD/CAM [25]

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV