    Comportamiento de una placa DCS 95° en una fractura de cadera

    Thumbnail
    View/Open
    Trabajo de Diploma Héctor Raúl Rodríguez Martínez.pdf (1.592Mb)
    Date
    2019
    Author
    Rodríguez Martínez, Héctor Raúl
    Metadata
    Show full item record
    Abstract
    La fractura de cadera constituye la complicación de la osteoporosis más grave y temida, tanto por sus repercusiones a corto, como a largo plazo, aunque también estas pueden ser provocadas por traumatismos de alta energía. Estas pueden ser consolidadas mediante una inmovilización con un yeso, aunque en algunos casos precisan de tratamiento quirúrgico, que conllevan una elevada estancia hospitalaria y generan una morbilidad importante, con gran incapacidad funcional como secuela. Se utilizan múltiples dispositivos para lograr la consolidación de las fracturas de cadera. Algunos sufren roturas antes de lograr una total sanación, ocasionando nuevas complicaciones, y poniendo en riesgo la salud del paciente. En esta investigación se presentan los resultados de análisis numéricos realizados a un modelo virtual de un implante placa DCS de 95°, con el objetivo de predecir su comportamiento en dos fracturas de fémur distintas Para la modelación del conjunto biomecánico hueso – implante se obtuvo un modelo computacional de un fémur humano. Los resultados muestran que el dispositivo resulta adecuado para el tratamiento de fracturas transtrocantéreas.
     
    Hip fracture is the most serious and feared complication of osteoporosis, both due to its short-term and long-term repercussions, although these can also be caused by high-energy trauma. These can be consolidated by immobilization with a cast, although in some cases they require surgical treatment, which entail a high hospital stay and generate an important morbidity, with great functional disability as a sequel. In addition, it is responsible for complications during the stay in the hospital, as well as during the year following the event. Multiple devices are used to achieve the consolidation of hip fractures. Some fail before achieving total healing, causing new complications to the trauma. This research presents the results of numerical analysis performed on a virtual model of a DCS 95° plate implant, with the aim of predicting its behavior in two different femur fractures. For the modeling of the biomechanical bone -implant set, a computational human femur model was obtained. The results show that the device is suitable for the treatment of transtrochanteric fractures.
     
    URI
    http://repositorio.uho.edu.cu/jspui/handle/uho/6286
    Collections
    • Trabajos de Diplomas de Ingeniería Mecánica [410]

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV