    Evaluación de la influencia de la eficiencia energética en los sistemas de climatización no centralizados

    Thumbnail
    View/Open
    Yoan Tomás Iñiguez Bermúdez.pdf (1.199Mb)
    Date
    2022
    Author
    Iñiguez Bermúdez, Yoan Tomás
    Metadata
    Show full item record
    Abstract
    En el presente trabajo investigativo se ha analizado la influencia del inadecuado uso en cuanto a la disposición de las tecnologías de climatización no centralizados, debido al mal manejo de las cargas térmicas por las limitaciones en la estimación del aporte térmico y las insuficiencias presentadas en los sistemas de clima, tanto en el Salón Vip del aeropuerto como en el centro de Nodos de la Universidad de Holguín. Para ello se planteó un procedimiento a partir del análisis de varias metodologías con las que se determinó los factores de mayor aporte térmico y la demanda real necesitada en cuanto a potencia de clima. Se realizó un diagnóstico energético, un análisis eléctrico y se comparó el resultado obtenido en ambos lugares con el calculado por métodos más simples demostrándose su fiabilidad y correcto uso para la determinación de las cargas térmicas, ya que los métodos simples que comúnmente se emplean se alejan de la realidad. En el caso del Salón VIP se obtuvo aproximadamente la necesidad de un 40% de clima menos al instalado mientras que en el centro de Nodos la necesidad de una mayor potencia en el sistema de climatización. Además se aportó información valiosa a través de las cuales se pudieron hacer varias propuestas de mejoras para los lugares desarrollados
     
    In the present investigative work, the influence of the inappropriate use in terms of the provision of non-centralized air conditioning technologies has been analyzed, due to the mismanagement of thermal loads due to the limitations in the estimation of the thermal contribution and the insufficiencies presented in the systems weather conditions, both in the VIP lounge of the airport and in the Node center of the University of Holguín. For this, a procedure was proposed based on the analysis of various methodologies with which the factors of greatest thermal input and the real demand needed in terms of climate power were determined. An energy diagnosis and an electrical analysis were carried out and the result obtained in both places was compared with that calculated by simpler methods, demonstrating its reliability and correct use for determining thermal loads, since the simple methods that are commonly used are far from of reality. In the case of the VIP Lounge, the need for approximately 40% less climate than the one installed was obtained, while in the Node center the need for more power in the air conditioning system. In addition, valuable information was provided through which several proposals for improvements could be made for the developed places
     
    URI
    http://repositorio.uho.edu.cu/xmlui/handle/uho/10099
    Collections
    • Maestría en Eficiencia Energética (PAAA) [22]

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Directora de la Biblioteca: Yoldis Leydi Mayo Batista

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV