Show simple item record

dc.contributor.advisorLaborde Brown, Reynaldo
dc.contributor.authorIñiguez Bermúdez, Yoan Tomás
dc.date.accessioned2026-06-04T14:53:28Z
dc.date.available2026-06-04T14:53:28Z
dc.date.issued2022
dc.identifier.citationIñiguez Bermúdez, Yoan Tomás.(2022). Evaluación de la influencia de la eficiencia energética en los sistemas de climatización no centralizados. Tesis de Maestría, Maestría en Eficiencia Energética, Universidad de Holguín.es_ES
dc.identifier.urihttp://repositorio.uho.edu.cu/xmlui/handle/uho/10099
dc.descriptionTesis presentada en opción al título académico de Máster en Eficiencia Energéticaes_ES
dc.description.abstractEn el presente trabajo investigativo se ha analizado la influencia del inadecuado uso en cuanto a la disposición de las tecnologías de climatización no centralizados, debido al mal manejo de las cargas térmicas por las limitaciones en la estimación del aporte térmico y las insuficiencias presentadas en los sistemas de clima, tanto en el Salón Vip del aeropuerto como en el centro de Nodos de la Universidad de Holguín. Para ello se planteó un procedimiento a partir del análisis de varias metodologías con las que se determinó los factores de mayor aporte térmico y la demanda real necesitada en cuanto a potencia de clima. Se realizó un diagnóstico energético, un análisis eléctrico y se comparó el resultado obtenido en ambos lugares con el calculado por métodos más simples demostrándose su fiabilidad y correcto uso para la determinación de las cargas térmicas, ya que los métodos simples que comúnmente se emplean se alejan de la realidad. En el caso del Salón VIP se obtuvo aproximadamente la necesidad de un 40% de clima menos al instalado mientras que en el centro de Nodos la necesidad de una mayor potencia en el sistema de climatización. Además se aportó información valiosa a través de las cuales se pudieron hacer varias propuestas de mejoras para los lugares desarrolladoses_ES
dc.description.abstractIn the present investigative work, the influence of the inappropriate use in terms of the provision of non-centralized air conditioning technologies has been analyzed, due to the mismanagement of thermal loads due to the limitations in the estimation of the thermal contribution and the insufficiencies presented in the systems weather conditions, both in the VIP lounge of the airport and in the Node center of the University of Holguín. For this, a procedure was proposed based on the analysis of various methodologies with which the factors of greatest thermal input and the real demand needed in terms of climate power were determined. An energy diagnosis and an electrical analysis were carried out and the result obtained in both places was compared with that calculated by simpler methods, demonstrating its reliability and correct use for determining thermal loads, since the simple methods that are commonly used are far from of reality. In the case of the VIP Lounge, the need for approximately 40% less climate than the one installed was obtained, while in the Node center the need for more power in the air conditioning system. In addition, valuable information was provided through which several proposals for improvements could be made for the developed placeses_ES
dc.language.isoeses_ES
dc.publisherUniversidad de Holguín, Facultad de Inganiería, Departamento de Ingeniería Mecánica.es_ES
dc.subjectCLIMATIZACION NO CENTRALIZADAes_ES
dc.subjectCARGAS TERMICASes_ES
dc.subjectDIAGNOSTICO ENERGETICOes_ES
dc.subjectNODOSes_ES
dc.subject.otherEFICIENCIA ENERGETICAes_ES
dc.subject.otherDIGITALIZACIONes_ES
dc.subject.otherANALISIS DE REDESes_ES
dc.subject.otherSERVIDORES WEBes_ES
dc.subject.otherAHORRO DE ENERGIA ELECTRICAes_ES
dc.subject.otherCONSUMO DE ENERGIAes_ES
dc.titleEvaluación de la influencia de la eficiencia energética en los sistemas de climatización no centralizadoses_ES
dc.typemasterThesises_ES