Show simple item record

dc.contributor.advisorUrquiza Salgado, Rosa Isabel
dc.contributor.advisorBatista Rodríguez, Carlos
dc.contributor.authorPérez Amador, Luis Daniel
dc.contributor.authorCéspedes Labrada, Willams Alejandro
dc.coverage.spatial1001296es_ES
dc.date.accessioned2017-04-03T16:22:57Z
dc.date.available2017-04-03T16:22:57Z
dc.date.issued2010
dc.identifier.urihttp://repositorio.uho.edu.cu/jspui/handle/uho/2398
dc.description.abstractEn el presente trabajo se realiza un estudio de algunas de las causas que influyen en los índices de consumo de combustible del emplazamiento de los grupos electrógenos pertenecientes a la Subestación Holguín 220 kV del municipio de Holguín, por estar por encima de los previstos. Dentro de los factores que pueden influir se estudiaron los métodos de aforo aplicados a los depósitos de combustible y el procedimiento de medición de la cantidad de combustible almacenada en ellos, para reducir el margen de error. En esta dirección, se propuso una fórmula alternativa que permite estimar el contenido de estos tanques cilíndricos horizontales de cabezas planas, con ayuda de un programa informático. Se investigó también sobre los distintos medidores de flujo, sus aplicaciones y beneficios, realizando una valoración técnico- económica de su instalación. Además, se hace un estudio de las pérdidas en litros de combustible Diesel y en moneda nacional para la mencionada empresa de generación distribuida en el período de mayo 2009 – mayo 2010. In the present work is carried out a deep study of some of the causes that may influence in the ratings of consumption at the location of the electrogen groups belonging to the Sub-station Holguín 220 kV of the municipality of Holguín, for being above of the foreseen. From the many factors that can influence in them, the seating capacity methods were studied and applied to fuel deposits and the procedure of measurement of the quantity of fuel stored in them, to reduce the margin for error. In this direction, it is intended an alternative formula that allows estimating the content of these horizontal cylindrical tanks of plane heads, with the help of a computer program. It was also investigated about the different meters of flow, their applications and benefits, carrying out a technician- economic valuation of their installation. Also, a study of the losses is made in litters of Diesel fuel and in national currency for the mentioned distributed generation company, in the period of May 2009 - May 2010.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Holguín Oscar Lucero Moya, Facultad de Ingeniería, Departamento de Ingeniería Mecánicaes_ES
dc.subjectGRUPOS ELECTROGENOS - HOLGUINes_ES
dc.subjectANALISIS ECONOMICOes_ES
dc.subject.otherGENERADORES ELECTRICOSes_ES
dc.subject.otherCOMBUSTIBLE DIESELes_ES
dc.subject.otherCONSUMO DE COMBUSTIBLEes_ES
dc.subject.otherENERGIA ELECTRICA - CONSUMOes_ES
dc.titleEstudio de algunos de los factores que influyen en los índices de consumo de los grupos electrógenos del emplazamiento Holguín 220 kVes_ES
dc.typebachelorThesises_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record