    Aspectos relacionados con el control del flujo secundario de agua en climatización centralizada.

    Thumbnail
    View/Open
    2012 - Jesús - Aspectos relacionados con el control del flujo.pdf (332.8Kb)
    Date
    2012
    Author
    Hechavarría Hernández, Jesús Rafael
    Montero Laurencio, Reineris
    Metadata
    Show full item record
    Abstract
    En este trabajo se realiza el ajuste del controlador proporcional integral incorporado en los variadores de velocidad utilizados en circuitos secundarios de agua fría en la climatización centralizada de un hotel. Quedó definida la ganancia proporcional y el tiempo de integración que garantiza un error mínimo de un kPa en el control de la presión. A partir de pruebas a lazo abierto se presenta un enfoque multivariable del sistema y se define la estructura de red neuronal artificial la cual predice el comportamiento de la presión, la potencia y temperatura de retorno, para un ajuste de 94%. La diferencia del trabajo entre el lazo abierto y lazo cerrado del accionamiento, próximas al mismo punto de operación indican el ahorro de 13% de energía eléctrica. In this paper the tuning of the proportional integral controller, incorporated in the variable frequency drive implemented on the secondary variable fl ow system of cold water of the centralized air conditioning system of a Hotel is carried out. The proportional gain and the time of integration that guarantee a minimum error of one kPa in the control of pressure were defi ned. A focus multi-variable of the system is presented. It is defi ned the structure of artifi cial neural network that beer it predicts the behaviour of the pressure, the power and return temperature with an adjustment of 94%. It is determined that there is a saving of 13% of electric power, in similar operation conditions, when using a control for closed loop with respect to a control for open loop.
    URI
    http://repositorio.uho.edu.cu/jspui/handle/uho/37
    Collections
    • CAD/CAM [25]

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV