dc.contributor.advisor | Hidalgo Batista, Elio Rafael | |
dc.contributor.author | Pérez Font, Pedro Luis | |
dc.coverage.spatial | 1001296 | es_ES |
dc.date.accessioned | 2018-06-28T14:40:13Z | |
dc.date.available | 2018-06-28T14:40:13Z | |
dc.date.issued | 2017 | |
dc.identifier.uri | http://repositorio.uho.edu.cu/jspui/handle/uho/4431 | |
dc.description.abstract | En el trabajo se aborda la necesidad de conocer la causa de rotura del cable de retención de las puntas de palas del aerogenerador S50-750 ubicado en el Parque Eólico Gibara 2. En este trabajo se determina a través de cálculos de resistencia, la tensión máxima, la fuerza centrífuga, la determinación del coeficiente de seguridad a la fatiga y su comparación con el coeficiente de seguridad admisible para estos cables y de aquí conocer su vida útil. Llegando a las siguientes conclusiones: que la causa de la rotura del cable es la fatiga, esto lo corrobora los cálculos realizados de resistencia donde se conoce que la fuerza centrífuga es la principal fuerza que actúa en el cable de retención sometiéndolo a fuerzas cíclicas en el tiempo y por tanto a la fatiga del mismo, hasta su rotura final y que el cable de retención de las puntas de palas del aerogenerador S50-750 del Parque Eólico Gibara 2, se rompe porque llega al fin de su vida útil, es decir, es sometido a diferentes cargas durante su explotación hasta que se rompe por fatiga del material. El conocimiento de estas causas facilita una correcta toma de decisiones relacionada con la explotación y los recursos financieros y humanos destinados al Parque Eólico de Gibara 2. | es_ES |
dc.description.abstract | This work addresses the need to know the cause of rupture of the retaining cable of the blade tips of wind turbine S50-750 located in the Wind Park 2 Gibara. In this work determines through resistance calculations, the maximum voltage, the centrifugal force, the determination of the fatigue safety coefficient and its comparison with the permissible safety coefficient for these cables and hence know their useful life. Coming to the following conclusions: that the cause of cable breakage is fatigue, this is corroborated by the calculations made of resistance where it is known that the centrifugal force is the main force acting on the retaining wire by subjecting it to cyclic forces in the Time and therefore to the fatigue of the same, until its final break and that the cable of retention of the tips of blades of the aerogenerator S50-750 of the Wind Farm 2, is broken because it reaches the end of its useful life, Is subjected to different loads during its operation until it is broken by fatigue of the material. The knowledge of these causes facilitates a correct decision making related to the exploitation and the financial and human resources destined to the Wind Farm of Gibara 2. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánica | es_ES |
dc.subject | CABLES DE RETENCION | es_ES |
dc.subject.other | AEROGENERADORES | es_ES |
dc.subject.other | ENERGIA EOLICA | es_ES |
dc.subject.other | FATIGA (MECANICA) | es_ES |
dc.subject.other | TOMA DE DECISIONES | es_ES |
dc.subject.other | PARQUES EOLICOS | es_ES |
dc.subject.other | FATIGA DE LOS MATERIALES | es_ES |
dc.subject.other | RESISTENCIA DE MATERIALES | es_ES |
dc.title | Estudio causal de la rotura del cable de retención de puntas de palas de los aerogeneradores modelo S50 – 750 del Parque Eólico Gibara 2 | es_ES |
dc.type | bachelorThesis | es_ES |