    Modelo matemático para la evaluación de los motocompresores herméticos en condiciones de clima tropical

    Thumbnail
    View/Open
    Leandro Ayarde Henríquez.pdf (1.307Mb)
    Date
    2013
    Author
    Ayarde Henríquez, Leandro
    Metadata
    Show full item record
    Abstract
    En la actualidad el refrigerador doméstico constituye un bien imprescindible, el cual, resulta ser uno de los mayores consumidores de energía eléctrica del hogar. Es por ello que se han multiplicado los esfuerzos para hacer que los sistemas frigoríficos sean cada vez más eficientes. Sin embargo, los modelos matemáticos existentes no contemplan las condiciones de países de clima tropical, luego cuando son importados por estos, se produce una disminución de la capacidad frigorífica del motocompresor hermético y el acortamiento de su vida útil. La tesis tiene como objetivo elaborar un modelo matemático que al considerar las características propias de países clima tropical permita determinar, de manera más cercana a la realidad, la capacidad frigorífica del motocompresor hermético. Los resultados arrojados por el modelo matemático revelan que la capacidad frigorífica de los tres motocompresores herméticos, casos de estudio, se comporta de manera similar, quedando rechazados a partir de 34 °C de temperatura ambiente, evidenciándose así su falta de idoneidad para ser importados por países de clima tropical
     
    Nowadays domestic refrigerator is a basic necessity which is an important user of electricity. Therefore efforts to improve the efficiency of these appliances have been increased. However the mathematical models do not reach for tropical climate countries' conditions hence there will occur losses of the compressor's capacity once it works under the conditions of a tropical climate country. The goal of this work is to elaborate a mathematical model that does involve the tropical climate ountries's conditions as well as it could predict, closer to reality, the capacity of hermetic compressors. The results reached using the mathematical model show the capacity of the three hermetic compressors, choosed for being studied, goes the same way hence all the hermetic compressors studied were rejected for 34 °C ambient temperature, showing their lack of fitting for being imported throw a tropical weather climate's country
     
    URI
    http://repositorio.uho.edu.cu/jspui/handle/uho/5241
    Collections
    • Maestría en Eficiencia Energética (PAAA) [11]

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV