| dc.description.abstract | El presente trabajo tuvo como objetivo lograr dosificaciones de hormigón hidráulico
que puedan ser usadas regularmente por la Empresa Constructora de Obras de
Arquitectura # 19 (ECOA 19) de modo que se logre la calidad requerida en la elaboración del hormigón en obras. Los ensayos de los áridos, el cemento y las
mezclas de pruebas se realizaron en el laboratorio de la Empresa Nacional de
Investigaciones Aplicadas (ENIA). Se utilizó el árido húmedo del Molino No. 1 de la
cantera 200 mil del municipio Gibara y para el análisis se tuvo en cuenta sus
propiedades para lograr resistencias de 15 Mega Pascal (MPa), 20 MPa, 25 MPa y
30 MPa con aditivo Dynamon SRC 20 y sin aditivo. Se investigaron varios métodos
de análisis de autores internacionales y nacionales y se asumió el de Vitervo O' Reilly Díaz para obtener la mezcla óptima de áridos y determinar proporciones para los ensayos. Las mezclas de prueba revelaron resultados satisfactorios y permitieron corregir las dosificaciones lo que disminuyó el consumo de cemento real sin afectar la resistencia del hormigón. | es_ES |
| dc.description.abstract | This study aimed to achieve concrete hydraulic dosages that can be used regularly by Works Construction Enterprise Architecture # 19 (ECOA 19) so that the quality required in the production of concrete works is achieved. Trials of aggregates, cement and mixtures tests were performed in the laboratory of the National Applied Research Company (ENIA). Mill the damp aggregate quarry No. 1 200 000 the municipality Gibara was used and the analysis took into account their properties to achieve resistors 15 Mega Pascal (MPa), 20 MPa, 25 MPa and 30 MPa additive Dynamon 20 SRC without additive. Various methods of analysis of international and national authors investigated and took Vitervo O' Reilly of Diaz to obtain the optimal mix of aggregates and determine proportions for testing. The test mixtures revealed satisfactory results and allowed correct dosages which reduced actual consumption of cement without affecting the strength of concrete. | es_ES |
| dc.language.iso | spa | es_ES |
| dc.publisher | Universidad de Holguín,Facultad de Ingeniería, Departamento de Construcciones | es_ES |
| dc.subject | DOSIFICACION | es_ES |
| dc.subject | HORMIGON CON ADITIVOS DYNAMON SRC 20 | es_ES |
| dc.subject | HORMIGON SIN ADITIVOS | es_ES |
| dc.subject | HORMIGON HIDRAULICO | es_ES |
| dc.subject | RESISTENCIA DEL HORMIGON | es_ES |
| dc.subject | MEZCLAS DE ARIDOS | es_ES |
| dc.subject.other | INGENIERIA CIVIL | es_ES |
| dc.subject.other | HORMIGON ARMADO | es_ES |
| dc.subject.other | MATERIALES DE CONSTRUCCION | es_ES |
| dc.subject.other | MEZLAS | es_ES |
| dc.title | Dosificaciones de hormigón con aditivo Dynamón SRC 20 y sin aditivo para la Empresa Constructora de Obras de Arquitectura ECOA 19 | es_ES |
| dc.type | bachelorThesis | es_ES |