Show simple item record

dc.contributor.advisorSegura Zaldívar, Pedro M.
dc.contributor.authorSalomón Salazar, Lorenzo Felipe
dc.date.accessioned2016-10-26T15:38:44Z
dc.date.available2016-10-26T15:38:44Z
dc.date.issued2009
dc.identifier.urihttp://repositorio.uho.edu.cu/jspui/handle/uho/587
dc.description.abstractEl presente trabajo de diploma titulado “Estimado de la Eficiencia Energética de la enfriadora CHAWT – 3204 del Hospital Pediátrico Octavio de la Concepción y la Pedraja” se ha realizado con el propósito de estimar el grado de Eficiencia con que funciona esta máquina, partiendo de mediciones de temperatura, tensión e intensidad de corriente realizadas a los consumidores (consolas). En el Capítulo 1 hace referencia a la historia de la climatización, definiciones y términos utilizados en el campo de la misma, así como algunas características de los sistemas de climatización centralizados tipo CHAWT, tipos de refrigerantes y factores a tener en cuenta a la hora de obtener la máxima carga térmica admisible. Dentro del capítulo 2 se encuentra el objeto social, misión y visión del Centro Hospitalario, caracterización de la enfriadora y las climatizadoras. Se realizaron cálculos para demostrar la cantidad de calor que se extrae y con que capacidad está trabajando en estos momentos el sistema de climatización No. 1 de dicho Hospital y de esta forma tener argumentos para dar un criterio más acertado acerca del sobreconsumo de electricidad de esta enfriadora modelo CHAWT – 3204 y la eficiencia que maneja la misma. Se hizo una breve valoración económica partiendo de las pérdidas de energía eléctrica detectada se dieron recomendaciones que servirán para futuras investigaciones, teniendo como base la labor realizada. The present investigation is titled Estimation of Energetic Efficiency of a cooler CHAWT – 3204 of the Hospital Octavio of Conception and the Pedraja. The Hospital has estimate the grade of Efficiency that machine itself works with this, acquiring the measurements of the temperature, tension and intensity of the current was obtain from the equipment ( consoles ) In Chapter 1 mentions the reference of the history of air conditioning, definitions and terms used as well as the characteristics of the centralized air conditioning systems type CHAWT, types of refrigerants and factors which takes into account of obtaining the maximum thermo admissible load. Within the chapter 2 the corporate purpose, mission and vision of the Hospital Centre, characterization of the cooling apparatus of the air conditioner. Calculations to demonstrate the amount of heat that is extracted and with that capability of working in the present moment, the N0 1 air conditioning system of the above mentioned Hospital and this way having arguments to give more opinion about the over consumption of electricity of this cooling model apparatus CHAWT – 3204 and its efficiency. A brief evaluation of detected losses of the electric energy and a little insight of the repercussion of these teams for the environment. Recommendations was given that will be useful for future investigations.es_ES
dc.language.isoeses_ES
dc.publisherUniversidad de Holguín Oscar Lucero Moya, Facultad de Ingeniería, Departamento de Ingeniería Mecánicaes_ES
dc.subjectENERGIA ELECTRICAes_ES
dc.subjectAIRE ACONDICIONADOes_ES
dc.subjectTEMPERATURA-MEDICIONes_ES
dc.subjectAHORROes_ES
dc.subjectEFICIENCIA ENERGETICAes_ES
dc.subjectCORRIENTES ELECTRICASes_ES
dc.titleEstimado de la Eficiencia Energética de la enfriadora CHAWT – 3204 del Hospital Pediátrico de Holguín “Octavio de la Concepción y la Pedraja”es_ES
dc.typeThesises_ES