| dc.description.abstract | La fractura de cadera constituye la complicación de la osteoporosis más grave y temida, tanto por sus repercusiones a corto, como a largo plazo, aunque también estas pueden ser provocadas por traumatismos de alta energía. Estas pueden ser consolidadas mediante una inmovilización con un yeso, aunque en algunos casos precisan de tratamiento quirúrgico, que conllevan una elevada estancia hospitalaria y generan una morbilidad importante, con gran incapacidad funcional como secuela. Se utilizan múltiples dispositivos para lograr la consolidación de las fracturas de cadera. Algunos sufren roturas antes de lograr una total sanación, ocasionando nuevas complicaciones, y poniendo en riesgo la salud del paciente.
En esta investigación se presentan los resultados de análisis numéricos realizados a un modelo virtual de un implante placa DCS de 95°, con el objetivo de predecir su
comportamiento en dos fracturas de fémur distintas Para la modelación del conjunto
biomecánico hueso – implante se obtuvo un modelo computacional de un fémur humano. Los resultados muestran que el dispositivo resulta adecuado para el tratamiento de fracturas transtrocantéreas. | es_ES |
| dc.description.abstract | Hip fracture is the most serious and feared complication of osteoporosis, both due to its short-term and long-term repercussions, although these can also be caused by high-energy trauma. These can be consolidated by immobilization with a cast, although in some cases they require surgical treatment, which entail a high hospital stay and generate an important morbidity, with great functional disability as a sequel. In addition, it is responsible for complications during the stay in the hospital, as well as during the year following the event. Multiple devices are used to achieve the consolidation of hip fractures. Some fail before achieving total healing, causing new complications to the trauma. This research presents the results of numerical analysis performed on a virtual model of a DCS 95° plate implant, with the aim of predicting its behavior in two different femur fractures. For the modeling of the
biomechanical bone -implant set, a computational human femur model was obtained. The results show that the device is suitable for the treatment of transtrochanteric fractures. | es_ES |
| dc.language.iso | spa | es_ES |
| dc.publisher | Universidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánica. | es_ES |
| dc.subject | PLACA DCS 95° | es_ES |
| dc.subject | FRACTURA DE CADERAS | es_ES |
| dc.subject.other | INGENIERIA MECANICA | es_ES |
| dc.subject.other | YESO | es_ES |
| dc.subject.other | IMPLANTES ORTOPEDICOS | es_ES |
| dc.subject.other | BIOMECANICA | es_ES |
| dc.subject.other | FEMUR - ANATOMIA | es_ES |
| dc.title | Comportamiento de una placa DCS 95° en una fractura de cadera | es_ES |
| dc.type | bachelorThesis | es_ES |