Show simple item record

dc.contributor.advisorRamón Téllez, Ana Lisandra
dc.contributor.advisorArencibia Ávila, Karel Joel
dc.contributor.authorCorrea Pérez, Sergio Javier
dc.coverage.spatial1001296es_ES
dc.date.accessioned2020-09-21T19:23:01Z
dc.date.available2020-09-21T19:23:01Z
dc.date.issued2019
dc.identifier.urihttp://repositorio.uho.edu.cu/jspui/handle/uho/6308
dc.description.abstractLa presente investigación persigue determinar el comportamiento real de los principales parámetros eléctricos de los refrigeradores existentes en Holguín, ya que no existe antecedentes de un estudio que permita conocer cuál es la conducta real de las variables eléctricas de los refrigeradores en condiciones reales de explotación y cómo influye su comportamiento en el consumo del mismo. Para ello a los refrigeradores objeto de estudio se le realizaron varias mediciones eléctricas con el Analizador de redes MetrelPowerQ Plus durante un período de 24 horas, con el objetivo de conocer su consumo de energía y evaluar su desempeño energético en comparación con los datos declarados en la etiqueta de fabricación del equipo. Conociendo el comportamiento eléctrico de los refrigeradores existentes en Holguín, se podrá diseñar una mejor estrategia que permita aumentar la eficiencia energética en el país, favoreciendo los procesos de selección y evaluación de estos equipos, a la economía del usuario y del país y al cuidado del medio ambiente. Se demostró que en todos los refrigeradores analizados independientemente de las condiciones de explotación el consumo de energía supera los valores establecidos por el fabricante llegando a ser de hasta un 200% respecto al valor obtenido de la etiqueta.es_ES
dc.description.abstractThe present investigation seeks to determine the real behavior of the main electrical parameters of existing refrigerators in Holguín, since there is no history of a study that allows to know what is the real behavior of the electric variables of refrigerators in real operating conditions and how its behavior influences its consumption. To this end, the refrigerators under study were subjected to several electrical measurements with the Metrel PowerQ Plus network analyzer during a period of 24 hours, with the objective of knowing their energy consumption and evaluating their energy performance in comparison with the data declared in the equipment manufacturing label. Knowing the electrical behavior of existing refrigerators in Holguín, a better strategy can be designed to increase the energy efficiency in the country, favoring the selection and evaluation processes of these equipment, the economy of the user and the country and the care of the environment. It was shown that in all the refrigerators analyzed, regardless of the operating conditions, the energy consumption exceeds the values established by the manufacturer, reaching up to 200% with respect to the value obtained from the label.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánicaes_ES
dc.subjectCOMPARACION ENERGETICAes_ES
dc.subjectTECNOLOGIAS DE REFRIGERACIONes_ES
dc.subjectPARAMETROS ELECTRICOSes_ES
dc.subject.otherINGENIERIA MECANICAes_ES
dc.subject.otherREFRIGERACION DOMESTICAes_ES
dc.subject.otherMEDICION ELECTRICAes_ES
dc.subject.otherCONSUMO DE ENERGIAes_ES
dc.subject.otherEFICIENCIA ENERGETICAes_ES
dc.titleComparación energética de las tecnologías de refrigeración domésticases_ES
dc.typebachelorThesises_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record