| dc.contributor.advisor | Ramón Téllez, Ana Lisandra | |
| dc.contributor.advisor | Arencibia Ávila, Karel Joel | |
| dc.contributor.author | Correa Pérez, Sergio Javier | |
| dc.coverage.spatial | 1001296 | es_ES |
| dc.date.accessioned | 2020-09-21T19:23:01Z | |
| dc.date.available | 2020-09-21T19:23:01Z | |
| dc.date.issued | 2019 | |
| dc.identifier.uri | http://repositorio.uho.edu.cu/jspui/handle/uho/6308 | |
| dc.description.abstract | La presente investigación persigue determinar el comportamiento real de los principales parámetros eléctricos de los refrigeradores existentes en Holguín, ya que no existe antecedentes de un estudio que permita conocer cuál es la conducta real de las variables eléctricas de los refrigeradores en condiciones reales de explotación y cómo influye su comportamiento en el consumo del mismo. Para ello a los refrigeradores objeto de estudio se le realizaron varias mediciones eléctricas con el Analizador de redes MetrelPowerQ Plus durante un período de 24 horas, con el objetivo de conocer su consumo de energía y evaluar su desempeño energético en comparación con los datos declarados en la etiqueta de fabricación del equipo. Conociendo el comportamiento eléctrico de los refrigeradores existentes en Holguín, se podrá diseñar una mejor estrategia que permita aumentar la eficiencia energética en el país, favoreciendo los procesos de selección y evaluación de estos equipos, a la economía del usuario y del país y al cuidado del medio ambiente. Se demostró que en todos los refrigeradores analizados independientemente de las condiciones de explotación el consumo de energía supera los valores establecidos por el fabricante llegando a ser de hasta un 200% respecto al valor obtenido de la etiqueta. | es_ES |
| dc.description.abstract | The present investigation seeks to determine the real behavior of the main electrical parameters of existing refrigerators in Holguín, since there is no history of a study that allows to know what is the real behavior of the electric variables of refrigerators in real operating conditions and how its behavior influences its consumption. To this end, the refrigerators under study were subjected to several electrical measurements with the Metrel PowerQ Plus network analyzer during a period of 24 hours, with the objective of knowing their energy consumption and evaluating their energy performance in comparison with the data declared in the equipment manufacturing label. Knowing the electrical behavior of existing refrigerators in Holguín, a better strategy can be designed to increase the energy efficiency in the country, favoring the selection and evaluation processes of these equipment, the economy of the user and the country and the care of the environment. It was shown that in all the refrigerators analyzed, regardless of the operating conditions, the energy consumption exceeds the values established by the manufacturer, reaching up to 200% with respect to the value obtained from the label. | es_ES |
| dc.language.iso | spa | es_ES |
| dc.publisher | Universidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánica | es_ES |
| dc.subject | COMPARACION ENERGETICA | es_ES |
| dc.subject | TECNOLOGIAS DE REFRIGERACION | es_ES |
| dc.subject | PARAMETROS ELECTRICOS | es_ES |
| dc.subject.other | INGENIERIA MECANICA | es_ES |
| dc.subject.other | REFRIGERACION DOMESTICA | es_ES |
| dc.subject.other | MEDICION ELECTRICA | es_ES |
| dc.subject.other | CONSUMO DE ENERGIA | es_ES |
| dc.subject.other | EFICIENCIA ENERGETICA | es_ES |
| dc.title | Comparación energética de las tecnologías de refrigeración domésticas | es_ES |
| dc.type | bachelorThesis | es_ES |