dc.description.abstractEn el presente trabajo se pretende dar solución a un problema existente en la localidad de Cristino Naranjo, el cual consiste en que aún no se conocen las dimensiones seguras del tanque elevado para agua en esa localidad que se ubicará sobre la estructura propuesta en investigaciones previas (Pérez, 2018). La investigación se desarrolló con el objetivo de que se conozcan estas dimensiones, durante el procesamiento del modelo se utilizan criterios tecnológicos e investigativos, que garantizan la generación de secuencias de ensamble del tanque elevado para agua donde se verifica el dimensionamiento del mismo con una capacidad de 37 m3 para garantizar su resistencia mecánica. Para realizar los cálculos de los esfuerzos estáticos se utilizó la herramienta computacional de diseño SolidWorks y para el análisis por elementos finitos, el complemento Simulation como herramienta de cálculo. Se programó la ecuación fundamental de la hidrostática para el cálculo de la presión del agua. La necesidad de la construcción de este tanque es muy importante para la localidad porque esta no cuenta con un depósito que sea capaz de satisfacer las necesidades de la población. Con la propuesta de diseño del tanque elevado para agua en la localidad de Cristino Naranjo será posible suministrarles el líquido a los habitantes del lugar y también podrá ser utilizado en cualquier otra localidad que lo necesite. Este modelo se podrá utilizar de referencia para su explotación, así como con fines docentes.es_ES
dc.description.abstractIn the present work is intended to solve a problem in the Cristino Naranjo town, which is that the safe dimensions of the elevated tank for water in that locality that will be located on the structure proposed in previous investigations (Pérez, 2018). The research was developed with the aim of knowing these dimensions, during the processing of the model technological and investigative criteria are used, which guarantee the generation of assembly sequences of the elevated tank for water where the sizing of the same is verified with a capacity of 37 m3 to guarantee its mechanical strength. To perform the calculations of static stress, the SolidWorks design computational tool was used, and for the finite element analysis the Simulation complement was used. The hydrostatics principal equation was programmed for the calculation of water pressure. The need for the creation of this tank is very important for the town because it does not have a tank that is able to meet the needs of the population. With the proposed design of the elevated water tank in the Cristino Naranjo town it will be possible to supply the liquid to the people of the place and it can also be used in any other location that needs it. This model can be used as a reference for its exploitation, as well as for teaching purposes.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánicaes_ES
dc.subjectCALCULO ESTRUCTURALes_ES
dc.subjectTANQUE DE AGUAes_ES
dc.subjectMETODOS NUMERICOSes_ES
dc.subjectPRESION DEL AGUAes_ES
dc.subject.otherINGENIERIA MECANICAes_ES
dc.subject.otherESTRUCTURAS (MECANICA)es_ES
dc.subject.otherHIDROSTATICAes_ES
dc.subject.otherAGUA - ABASTECIMIENTOes_ES
dc.titleCálculo estructural por métodos numéricos de un tanque para agua de 37 m3 en la localidad de Cristino Naranjoes_ES