| dc.contributor.advisor | Estrada Cingualbres, Roberto Andrés | |
| dc.contributor.author | Feria Basulto, Alejandro | |
| dc.coverage.spatial | 1001296 | es_ES |
| dc.date.accessioned | 2020-10-19T15:03:44Z | |
| dc.date.available | 2020-10-19T15:03:44Z | |
| dc.date.issued | 2014 | |
| dc.identifier.uri | http://repositorio.uho.edu.cu/jspui/handle/uho/6439 | |
| dc.description.abstract | En esta investigación se presentan los resultados de los estudios biomecánicos realizados a cuatro variantes, de uno de los fijadores internos más utilizados en nuestro país para la consolidación de las fracturas de fémur en su parte proximal, el Implante Dinámico de Cadera o placa DHS (Dynamic Hip Screw) por sus siglas en ingles. Estas variantes difieren en la longitud de la placa y por ende en la cantidad de tornillos de corticales usados para fijar la misma a la diáfisis del fémur. Estos estudios se realizan durante y después de retirados los implantes, para lograr esto se hace necesario la utilización del software profesional SolidWorks 2013 / Premium, el cual trae incorporado como módulo adicional, un paquete de análisis por elementos finitos, SolidWorks Simulation, permitiendo este último el cálculo de las tensiones de Von Mises en los implantes, pudiéndose determinar las zonas donde se concentran estas tensiones y donde se alcanzan sus valores máximos. También se conocen las tensiones normales en el eje longitudinal del fémur, que surgen en el mismo producto a las cargas mecánicas propias del peso y la acción de los músculos durante la marcha y a raíz de la utilización de dichos implantes durante y después de retirados estos, así como el por ciento del volumen del fémur que se somete a tracción o a compresión, todos estos estando el fémur en su estado normal de carga monopodal. | es_ES |
| dc.description.abstract | In this investigation show up the results of the biomechanical education accomplished to four variants, of one of the internal fixers more used in our country for the consolidation of the fractures of femur in your part proximal, plate DHS (Dynamic Hip Screw).These variants differ in the length of the plate and as a consequence in the quantity of screws of cortical used to fix the same one on the diafisis of the femur. These education come true during and after pensionaries the implantations, in order to achieve this the utilization of the professional software becomes necessary SolidWorks 2013 Premium, which brings incorporated like additional module, a parcel of analysis for finite elements, SolidWorks Simulation, permitting this last the calculation of the tensions of Von Mises in the implantations, being able to determining zones where concentrate these tensions and where they catch up with its maximum values. Also are acquainted the normal tensions in the longitudinal axis of the femur, that they happen in the same product to the mechanical own loads of the weight and the action of the muscles during the parade and because of the utilization of the aforementioned implantations during and after pensionaries these, as well as the percent of the volume of the femur that submits to traction or to compression, all these being the femur in your normal state of mono-foot-related load. | es_ES |
| dc.language.iso | spa | es_ES |
| dc.publisher | Universidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánica | es_ES |
| dc.subject | ESTUDIO BIOMECANICO | es_ES |
| dc.subject | FIJADORES INTERNOS | es_ES |
| dc.subject | TORNILLOS CORTICALES | es_ES |
| dc.subject | DIAFISIS DE FEMUR | es_ES |
| dc.subject.other | INGENIERIA MECANICA | es_ES |
| dc.subject.other | FEMUR-FRACTURAS | es_ES |
| dc.subject.other | TORNILLOS | es_ES |
| dc.subject.other | INJERTOS OSEOS | es_ES |
| dc.subject.other | OSTEOSINTESIS | es_ES |
| dc.title | Estudio biomecánico del conjunto placa DHS- hueso en la consolidación de las fracturas proximales del fémur | es_ES |
| dc.type | bachelorThesis | es_ES |