Show simple item record

dc.contributor.advisorArancibia Ávila, Karel Joel
dc.contributor.authorAyarde Henríquez, Leandro
dc.coverage.spatial1001296es_ES
dc.date.accessioned2019-04-05T13:39:55Z
dc.date.available2019-04-05T13:39:55Z
dc.date.issued2013
dc.identifier.urihttp://repositorio.uho.edu.cu/jspui/handle/uho/5241
dc.description.abstractEn la actualidad el refrigerador doméstico constituye un bien imprescindible, el cual, resulta ser uno de los mayores consumidores de energía eléctrica del hogar. Es por ello que se han multiplicado los esfuerzos para hacer que los sistemas frigoríficos sean cada vez más eficientes. Sin embargo, los modelos matemáticos existentes no contemplan las condiciones de países de clima tropical, luego cuando son importados por estos, se produce una disminución de la capacidad frigorífica del motocompresor hermético y el acortamiento de su vida útil. La tesis tiene como objetivo elaborar un modelo matemático que al considerar las características propias de países clima tropical permita determinar, de manera más cercana a la realidad, la capacidad frigorífica del motocompresor hermético. Los resultados arrojados por el modelo matemático revelan que la capacidad frigorífica de los tres motocompresores herméticos, casos de estudio, se comporta de manera similar, quedando rechazados a partir de 34 °C de temperatura ambiente, evidenciándose así su falta de idoneidad para ser importados por países de clima tropicales_ES
dc.description.abstractNowadays domestic refrigerator is a basic necessity which is an important user of electricity. Therefore efforts to improve the efficiency of these appliances have been increased. However the mathematical models do not reach for tropical climate countries' conditions hence there will occur losses of the compressor's capacity once it works under the conditions of a tropical climate country. The goal of this work is to elaborate a mathematical model that does involve the tropical climate ountries's conditions as well as it could predict, closer to reality, the capacity of hermetic compressors. The results reached using the mathematical model show the capacity of the three hermetic compressors, choosed for being studied, goes the same way hence all the hermetic compressors studied were rejected for 34 °C ambient temperature, showing their lack of fitting for being imported throw a tropical weather climate's countryes_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Holguín, Facultad de Ingeniería, Departamento de Ingeniería Mecánica.es_ES
dc.subjectCONSUMO DE ENERGIA ELECTRICAes_ES
dc.subjectREFRIGERADOR DOMESTICOes_ES
dc.subject.otherENERGIA - CONSUMOes_ES
dc.subject.otherFRIGORIFICOSes_ES
dc.subject.otherMOTOCOMPRESORESes_ES
dc.subject.otherAHORROes_ES
dc.subject.otherMODELOS MATEMATICOSes_ES
dc.titleModelo matemático para la evaluación de los motocompresores herméticos en condiciones de clima tropicales_ES
dc.typemasterThesises_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record