    Carga térmica y consumo energético en edificación turística con climatización centralizada a flujo variable.

    Thumbnail
    View/Open
    2011 - Jesús - CARGA TÉRMICA Y CONSUMO ENERGÉTICO.pdf (507.8Kb)
    Date
    2011
    Author
    Montero Laurencio, Reineris
    Hechavarría Hernández, Jesús Rafael
    Borroto Nordelo, Aníbal
    Metadata
    Show full item record
    Abstract
    En el presente trabajo se determina la carga térmica de una edificación que cuenta con un Sistema de Climatización Centralizada por Agua Helada (SCCAH) a flujo variable. Los cálculos se realizaron para todo un año característico para definir: los horarios de mayor carga térmica de cada habitación, la distribución de las ganancias de calor, las curvas de carga térmica máxima y el comportamiento al aplicar una estrategia ocupacional. Se presenta la estructura de un modelo basado en Redes Neuronales Artificiales de la carga térmica del edificio y los resultados generales de una modelación similar para cada habitación. Los modelos permiten sustituir al simulador de carga térmica y facilitan la preedición del consumo de energía. Se compara la potencia eléctrica necesaria en la bomba para una ocupación promedio y una ocupación con estrategia ocupacional basada en utilizar primero las habitaciones de menor carga térmica, apreciándose un ahorro promedio de un 18 %. In this paper the thermal load of a building which has a centralized air conditioning system for variable flow is determined. The calculations were carried out for an entire characteristic year to define: the schedules of bigger thermal load of each room, the distribution of the earnings of heat, the curves of load thermal maxim and the behavior when applying an occupational strategy. It is presented the structure of a model based on Artificial Neural Network of the thermal load of the building and the general results of a similar modeling for each room. The models allow to substituting the load thermal simulation and make easy the energy consumption prediction. The necessary electric power is compared in the bomb for an occupation average and an occupation with occupational strategy based on using the rooms of smaller thermal load first, being appreciated a saving average of 18%.
    URI
    http://repositorio.uho.edu.cu/jspui/handle/uho/35
    Collections
    • CAD/CAM [25]

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Director de la Biblioteca: Dr.C. Carlos Rafael Batista Matamoros

    Portal de la Biblioteca
    Contact Us | Send Feedback
    Theme by 
    Atmire NV